Flow Metrix, Inc. ::  water pipeline leak noise source place detection digital tools, equipment
ZCorr
Comparative Analysis of Zcorr Versus Other Correlating Logger Systems
 

Feature ZCorr Other Correlating Loggers
    
   Logger Battery Life
Warranted
  • 3 years
  • not published
Expected
  • 10 years or 1,500 recordings (whichever comes first)
  • 5 years
    
   Logger Recording
Recording gain
  • Up to 800V/g
  • Not published
Digital accuracy
  • 23 bits (1 part in 500,000)
  • 12 bits (1 part in 4,096)
Intelligent data encoding
  • Yes
  • No
Maximum no. of readings
  • Up to 4,000,000; determined intelligently by logger
  • 650,000 – standard (expandable to 1,350,000 on request)
Synchronization
  • 1 part in 100 million
  • Not published
    
   PC Communications / Data Downloading
Hardware
  • ZCorr docking station with 8 plugin, cable – less logger receptacles
  • Fixed 2, 6, or 12 logger interface units with cabled logger connections
Data transfer technology
  • USB
  • RS – 232 serial
Data transfer rate
  • 1,024 kbps (actual)
  • Up to 115.2 kbps (maximum)
Download time
  • 10 seconds or less per logger
  • Not published
    
   PC Software – Leak Pinpointing Analysis
Filtering methods
  • ALFA™
  • Automatic
  • Manual
  • Not Available
  • Automatic
  • Manual
Correlation assessment
  • Correlation Score of 0 – 100
  • Correlation results color – coded
Data management
  • ZCorr data manager, database features, search, sort, export to Windows & GIS programs
 
   